Specification

※ Max operating load: 2.72kN
※ Compatible ropes: X-Monster SHIELD PRO or Marlow Ropes PROTEC 500 only

Item Specification Notes
Main Body Weight 5.9 kg Cordless screwdriver not included
Dimensions 250mm × 190mm × 160mm Cordless screwdriver not included
Compatible Rope For use with X-Monster SHIELD PRO or Marlow Ropes PROTEC 500 only Before use, always soak the rope in water for at least one night and dry in the shade to remove wax.
Compatible Rope Diameter 11.0mm–11.5mm —
Power Source Cordless screwdriver (sold separately) ※ Impact driver strictly prohibited
Recommended Screwdriver Cordless screwdriver with battery capacity of 36V 2.5Ah or higher and IPX6 or higher water resistance 2,000 rpm or higher recommended
Operating Range Battery 40Vmax 2.5Ah, screwdriver at 2000rpm: approx. 50m Battery 100% charged, 2.00kN load, ambient temp. 20°C
Battery 40Vmax 5.0Ah, screwdriver at 2000rpm: approx. 100m Battery 100% charged, 2.00kN load, ambient temp. 20°C
Max Gear Input RPM 3,000 rpm —
Performance Max Operating Load 2.72kN —
Ascent Speed 2000 rpm: 8.0 m/min 2.72kN load (ambient temp. 20°C)
2600 rpm: 10.0 m/min 2.72kN load (ambient temp. 20°C)
3000 rpm: 12.0 m/min 2.72kN load (ambient temp. 20°C)
Descent Speed Within 1.0 m/s (ambient temp. 20°C, load less than 2.00kN) When the load is small or temperature is low, the grease inside the gearbox may harden, potentially preventing lowering.
Within 0.5 m/s (ambient temp. 20°C, load 2.00kN or more)
Water/Dust Resistance IP56 (When combined with an IPX6 rated cordless screwdriver, usable in rainy weather.) IEC60529, JISC0920
Brake Manual band brake —
Noise Level 76 dB (cordless screwdriver operating sound) In-house testing / noise meter
Life Usage No specific limit —
Warranty 1 year, or 10 years with Maintenance Pack Warranty details described in this manual
Inspection Interval Every 800 hours or every 3 years, whichever comes first Additional charges apply. Free with Maintenance Pack.
Operating Temp. -10°C to 45°C —
Other Accessories Case ×1, Input tool ×1, Instruction manual ×1 —
Continuous Use 1 battery (under maximum operating load) A 15-minute break is required after each battery use. (Precaution for cordless screwdriver use)
Heat Protection None —
Standard CE certification and EN standard acquisition in progress —

※ Manage the torque of the cordless screwdriver to ensure the load does not exceed the maximum operating load.
※ This product is designed to perform optimally at an input rotation speed of 3,000 rpm.
※ Data may vary depending on the cordless screwdriver manufacturer and battery type.
※ Specifications are subject to change without notice at the company’s discretion.